Clean up man page

This commit is contained in:
Martin Lund 2024-04-12 00:23:04 +02:00
parent 418a43d96e
commit 5eb649278a

View file

@ -21,19 +21,19 @@ devices for basic I/O operations.
Set baud rate [bps] (default: 115200).
.TP
.BR \-d ", " "\-\-databits 5" | 6 | 7 | 8
.BR \-d ", " "\-\-databits " 5 | 6 | 7 | 8
Set data bits (default: 8).
.TP
.BR \-f ", " "\-\-flow hard" | soft | none
.BR \-f ", " "\-\-flow " hard | soft | none
Set flow control (default: none).
.TP
.BR \-s ", " "\-\-stopbits 1" | 2
.BR \-s ", " "\-\-stopbits " 1 | 2
Set stop bits (default: 1).
.TP
.BR \-p ", " "\-\-parity odd" | even | none | mark | space
.BR \-p ", " "\-\-parity " odd | even | none | mark | space
Set parity (default: none).
@ -191,23 +191,23 @@ If defining more than one flag, the flags must be comma separated.
.RE
.TP
.BR " \-\-input\-mode " \fInormal|hex
.BR " \-\-input\-mode " normal|hex
Set input mode. In hex input mode bytes can be sent by typing the
\fBtwo-character hexadecimal\fR representation of the value, e.g.: to send
\fI0xA\fR you must type \fI0a\fR or \fI0A\fR.
\fBtwo-character hexadecimal\fR representation of the 1 byte value, e.g.: to
send \fI0xA\fR you must type \fI0a\fR or \fI0A\fR.
Default value is "normal".
.TP
.BR " \-\-output\-mode " \fInormal|hex
.BR " \-\-output\-mode " normal|hex
Set output mode. In hex mode each incoming byte is printed out as a hex value.
Set output mode. In hex mode each incoming byte is printed out as a 1 byte hex value.
Default value is "normal".
.TP
.BR \-c ", " "\-\-color " \fI0..255|bold|none|list
.BR \-c ", " "\-\-color " 0..255|bold|none|list
Colorize tio text using ANSI color code value ranging from 0 to 255 or use
"none" for no color or use "bold" to apply bold formatting to existing system