Add --log-append option which makes tio append to any existing log file.
This also changes the default behaviour of tio from appending to
overwriting any existing log file. Now you have to use this new option
to make tio append.
The response wait feature waited for a line response, a string
terminated with either CR or NL. However, some devices may send a CR and
then their line content and then NL. This means tio will quit before
receiving and printing the line response. To solve this we simply ignore
the CR character and only consider lines terminated with a NL character.
This should work for all devices as lines are AFAIK always terminated
with either CRNL or a NL.
Accept "true", "enable", "on", "yes", "1" as true values, their
counterparts as false ones. Check integer values for errors and range.
Warn about ignored (e.g. misspelled) options.
Check getenv() return value for NULL.
Rename "tiorc" to "config", as it's a static INI file, not an executable
"run commands".
Fix regression so that it is possible to send the prefix key code to the
remote tio session without local tio session reacting to same key code
(quitting etc.).
Add key command 'ctrl-t f' which will toggle log on/off.
If no log filename has been specified via the 'log-filename' option then
tio will automatically generate a new log filename every time the log
feature is toggled on. Meaning, when toggled multiple times, multiple
log files will be generated.
However, if a log filename has been specified, tio will only write and
append to that same file.
Print the 2 character hex code that you input in hex mode but then
delete it before sending. This way it is easier to keep track of what
you are inputting. It basically mimics the ctrl-shift-u input mechanism
that is used to input unicode.